Installing in walls: notching and chasing
Domestic Wiring · Lesson 27 · Beginner
Purpose
Route concealed cables in walls while coordinating prescribed zones, additional protection, penetration depth, structure, fire, and future fixings.
Learning objectives
- Explain prescribed wall zones
- Assess depth and additional protection
- Protect structure
- Document concealed routes
Concealed cable safety combines electrical rules with how occupants later drill, nail, alter, or repair the building. A straight-looking route is not automatically a recognised zone.
Core theory
Current BS 7671 defines permitted zones relative to visible accessories and wall edges/ceilings, with separate solutions for sufficient depth or suitable mechanical protection/earthed containment.
RCD additional protection may be required for concealed cables even when routed in prescribed zones; it does not remove route, enclosure, or mechanical requirements.
Chases and notches must comply with structural guidance and avoid weakening joists, lintels, fire barriers, acoustic layers, damp control, and other services.
| Term | Meaning | Symbol | Unit |
|---|---|---|---|
| Prescribed zone | Recognisable area where concealed cable may be expected | Not applicable | Not applicable |
| Chase | Channel cut into a wall for services | Not applicable | Not applicable |
| Mechanical protection | Protection against penetration or physical damage | Not applicable | Not applicable |
Assumptions: No earthed protection or sufficient depth shown.
- Zone: A diagonal between accessories is not established as a prescribed route.
- RCD: Additional protection does not make an unrecognisable route acceptable by itself.
- Redesign: Use a compliant zone or another current permitted protective method, then verify structure and circuit.
No; reroute or provide a fully compliant alternative protective arrangement.
Reasonableness check: Future drilling risk remains even though an RCD may reduce some consequences.
- Treating RCD as mechanical armour
- Assuming any line between accessories is a zone
- Cutting structural chases from electrical guidance alone
Where this appears in practice
Safe routing is essential in new work, rewires, extensions, and repair after building alterations.
Knowledge check
Does 30 mA RCD protection allow any concealed wall route?
No. Route and mechanical/depth requirements remain.
Answer: No. Route and mechanical/depth requirements remain.
Practical exercise
Draw allowed conceptual zones around accessories on a sample wall, then flag routes needing exact current-standard dimensions.
Summary
- Concealed routes must be predictable
- RCD is additional protection
- Structural rules also govern chases
Sources and review
- BS 7671:2018+A4:2026 model EICR schedule: IET; Amendment 4:2026; United Kingdom
- Wiring Regulations Help: Electrical Safety First; Current online technical guidance; United Kingdom
- Electrical safety: Approved Document P: UK Government; Current online edition; England
- Structure: Approved Document A: UK Government; Current online edition; England
Editorial review date: 2026-08-21. Professional electrical review is pending.