Course syllabusCourse overview
01LED Technology
  1. ReadHow LEDs produce light: p-n junction
  2. ReadEfficacy: lumens per watt explained
  3. ReadLED chip formats: COB, SMD, filament
  4. ReadThermal management: heatsinks and junction temperature
  5. quizLED technology quiz
02Driver Circuits
  1. ReadConstant current vs constant voltage drivers
  2. ReadDriver efficiency and power factor
  3. ReadDimming methods: PWM, 0-10V, DALI
  4. ReadDriver selection and compatibility
  5. quizDriver circuit quiz
03Emergency Lighting
  1. ReadBS 5266 categories: escape, standby, high-risk
  2. ReadSelf-contained vs central battery systems
  3. ReadMaintained vs non-maintained operation
  4. ReadTesting requirements and log books
  5. quizEmergency lighting quiz
04Lux Calculations
  1. ReadIlluminance, luminous flux, and efficacy
  2. ReadLumen method: average illuminance
  3. ReadRoom index, UF, and MF
  4. exerciseLux calculation worked example
05Lighting Control & Quality
  1. ReadColour temperature: warm, neutral, cool white
  2. ReadColour rendering index (Ra/CRI)
  3. ReadGlare: UGR and how to reduce it
  4. ReadSmart lighting systems: DALI 2 and IoT
  5. quizFinal assessment
Lesson · 7min
LUMEN METHOD · ILLUMINANCEluminaire · lmwork plane · area AEav = N·F·UF·MF÷ Alux (lm/m²)
Lesson contents 0%

In this lesson

PurposeCore theoryWorked exampleKnowledge checkSources

In this lesson

PurposeCore theoryWorked exampleKnowledge checkSources
0% read
ElectraCore lesson handout

Smart lighting systems: DALI 2 and IoT

Led Lighting · Lesson 23 · Intermediate

IntermediateReview: professional review pending

Purpose

Design DALI-2 and IoT lighting as commissioned control systems with offline/failure, security and privacy requirements.

Before you beginLED/driver fundamentals · Basic fire safety and arithmetic

Learning objectives

  • Define the design boundary
  • Use current product/project evidence
  • Calculate with stated assumptions
  • Verify maintained and failure performance

DALI-2 provides certified interoperable controlgear/control devices on a local bus; IoT platforms can add gateways, analytics and remote management. Connectivity does not replace local safe operation.

COLOUR GLARE AND SMART CONTROLCOLOUR GLARE AND SMART CONTROLDRIVERLEDlight · heatinput · regulation · junction · optics · control · environment

Core theory

Verify exact DALI-2 products in the public database, allowed parts/features, bus power/current/voltage drop, addressing, groups, scenes, sensors and emergency DT1 behavior.

Specify power-up/system-failure levels, manual override, occupancy/daylight logic, time schedules, emergency override, commissioning backup and replacement workflow.

For IP/cloud gateways define network segmentation, authentication, updates, encryption, logging, data minimization, retention, ownership and operation during internet/cloud outage. Do not expose safety testing to insecure remote control.

Terms, symbols, and units
TermMeaningSymbolUnit
DALI-2Certified IEC 62386-based digital lighting ecosystemNot applicableNot applicable
GatewayBridge between control protocols/networksNot applicableNot applicable
Failure levelDeclared light output after communication/system failureNot applicableNot applicable
Worked exampleA cloud outage removes schedules, but a local DALI application controller remains healthy.

Assumptions: Supplied values are fictional design inputs; Exact current standards and photometric/product data remain governing.

  1. Architecture: Local control can continue if scenes/logic and time dependencies are locally available.
  2. Define: Specify fallback level/manual override and behavior if controller or bus also fails.
  3. Test: Commission offline, gateway-failure and restoration states, not just normal cloud control.

Design for documented local operation/fallback; cloud availability must not be a single point of basic lighting control.

Reasonableness check: The answer distinguishes average screening from point, uniformity, glare, emergency and maintained-performance requirements.

Common mistakes
  • Treating standby lighting as identical to escape lighting
  • Using initial lumens without utilization or maintenance losses
  • Selecting color quality or glare from one headline number

Where this appears in practice

Complete lighting design coordinates visual task, occupants, fire strategy, photometry, emergency modes, controls, energy, maintenance and verification.

SafetyEmergency systems are life-safety equipment. Never disable charging, monitoring or test records; schedule duration tests without compromising occupancy safety and replace batteries/luminaires from approved evidence. Control work at height and live electrical hazards.
Local code checkConfirm current BS 5266-1:2025, BS EN 1838/50172 and fire-risk strategy, current SLL/CIBSE and workplace/task lighting criteria, photometric files, manufacturer emergency spacing tables, BS 7671, DALI-2 database status, cybersecurity/privacy policy and statutory maintenance records. Generic lux or UGR calculations do not replace project photometric/emergency design and verification.

Knowledge check

Does a DALI-2 logo on one device prove the complete multi-vendor system is commissioned?

No. Certification supports interoperability; design, addressing, features and tests remain.

Answer: No. Certification supports interoperability; design, addressing, features and tests remain.

Practical exercise

Create an offline/failure/cyber/privacy test matrix for a DALI-2 system with IoT gateway.

Summary

  • Emergency category follows risk and activity
  • Average lux is only one design metric
  • Controls must fail to a documented safe/useful state

Sources and review

  • BS 5266-1:2025: Emergency lighting code of practice: BSI; 2025; United Kingdom
  • SLL Code for Lighting: CIBSE / Society of Light and Lighting; Current edition and application guidance must be confirmed; United Kingdom
  • CIE position statement on colour quality metrics: CIE; Second edition, 2025; International
  • DALI-2 and DALI Emergency certification: DALI Alliance; Current product database/status must be checked; International

Editorial review date: 2026-08-22. Professional electrical review is pending.